HP StorageWorks P9000 Tiered Storage Manager Software 7.1.1 CLI Reference Guide (TB585-96014, September 2011)

DescriptionItem
The drive capacity of the parity group to which the unused capacity belongs (units:
GB)
diskCapacityInGB
NOTE:
If parity group information cannot be obtained, Unknown is displayed for some output items.
Example and execution results
Command execution example (1):
In this example, the GetFreeSpaces command obtains the information about unused capacity
in the storage system XP12000@10.208.151.151.
htsmcli GetFreeSpaces subsystemname="XP12000@10.208.151.151"
Execution results (1):
RESPONSE:
List of 1 Subsystem elements:
An instance of Subsystem(1 of 1)
name=XP12000@10.208.151.151
serialNumber=12345
List of 2 FreeSpace elements:
An instance of FreeSpace(1 of 2)
arrayGroupName=1-1-1
freeSpaceNumber=1
capacityInKB=22,528
totalFreeCapacityInKB=741,416,632
emulationType=OPEN-V
RAIDLevel=RAID5(3D+1P)
subsystemVendor=HP
diskType=-
diskRPM=10,000
diskCapacityInGB=268
An instance of FreeSpace(2 of 2)
arrayGroupName=1-1-1
freeSpaceNumber=507
capacityInKB=22,528
totalFreeCapacityInKB=741,416,632
emulationType=OPEN-V
RAIDLevel=RAID5(3D+1P)
subsystemVendor=HP
diskType=-
diskRPM=10,000
diskCapacityInGB=268
Command execution example (2):
In this example, the GetFreeSpaces command obtains the information about the unused capacity
in two storage systems named XP12000#14000.
CLI Reference Guide 175