HP StorageWorks P9000 Tiered Storage Manager Software 7.1.1 CLI Reference Guide (TB585-96014, September 2011)

For details about the restrictions on specifying other spaces, empty character strings, or symbolic
characters, or about whether the specifiable character string is case sensitive, see Table 11.
Table 8 Range of valid property values for volume filter conditions
Specifiable characters or valuesOperatorsProperty name
An integer from 0 to 100
<, <=, =, <>, >,
>=
ArrayGroupBusyRate
#1
An integer from 0 to 100
<, <=, =, <>, >,
>=
ArrayGroupMaxBusyRate
#1
Simplex
P-VOL
S-VOL
SP-VOL
=, <>
BusinessCopy
( BusinessCopyXP )
Specify a positive integer, or a positive integer
with a unit. (For example, 256, 500KB, or
10MB.)
If a value other than Block is specified for
units, or if units are omitted, an integer from
0 to 9,223,372,036,854,775,807 when
the value is converted to units of KB.
If Block is specified for units, an integer from
0 to 9,223,372,036,854,775,807.
The units you can specify are KB, MB, GB,
TB, and Block. KB is the default unit.
#2
<, <=, =, <>, >,
>=
Capacity
An integer from 0 to 31
=, <>CLPRNumber
Specify a positive integer, or a positive integer
with a unit. (For example, 256, 500KB, or
10MB.)
Specify an integer from 0 to
281,474,976,710,653KB
The units you can specify are KB, MB, GB,
and TB. KB is the default unit.
#2
<, <=, =, <>, >,
>=
ConsumedCapacity
An integer from 0 to 100
<, <=, =, <>, >,
>=
ConsumedCapacityPercentage
Simplex
P-VOL
S-VOL
=, <>
ContinuousAccessAsynchronous
(
ContinuousAccessXPAsynchronous
)
Simplex
P-VOL
S-VOL
SP-VOL
JNL-VOL
=, <>
ContinuousAccessJournal
( ContinuousAccessXPJournal )
Filter conditions that can be used in the CLI46