HP StorageWorks P9000 Tiered Storage Manager Software 7.1.1 CLI Reference Guide (TB585-96014, September 2011)

Detailed information about MegaTechUSP600-Primary and MegaTechUSP600-Secondary
is output. The error information that begins with List of 1 ErrorInfo elements: is displayed
at the end of the information about MegaTechUSP600-Secondary because refreshStatus
of MegaTechUSP600-Secondary is Failure.
RESPONSE:
List of 2 StorageDomain elements:
An instance of StorageDomain(1 of 2)
name=MegaTechXP12000-Primary
totalCapacityInGB=8,552
usedCapacityInGB=6,576
usedCapacityPercentage=77
freeCapacityInGB=1,975
freeCapacityPercentage=23
numberOfSubsystems=2
numberOfStorageTiers=0
numberOfMigrationGroups=0
refreshStatus=Success
lastRefreshedTime=2011/08/19 21:43:13
controllerSerialNumber=14011
controllerDisplayModel=XP12000
controllerName=XP12000@10.208.151.151
logicalDKCNumber=
description=XP12000-Primary
An instance of StorageDomain(2 of 2)
name=MegaTechXP12000-Secondary
totalCapacityInGB=Unknown
usedCapacityInGB=Unknown
usedCapacityPercentage=Unknown
freeCapacityInGB=Unknown
freeCapacityPercentage=Unknown
numberOfSubsystems=Unknown
numberOfStorageTiers=3
numberOfMigrationGroups=3
refreshStatus=Failure
lastRefreshedTime=
controllerSerialNumber=59432
controllerDisplayModel=XP12000
controllerName=Unknown
logicalDKCNumber=
description=XP12000-Secondary
List of 1 ErrorInfo elements:
An instance of ErrorInfo(1 of 1)
message=KATS62010-E message-contents
ModifyStorageDomain
The ModifyStorageDomain command can be used to change information (the name or description)
for a storage domain.
Note that information cannot be changed for storage domains in the following states:
Storage domains that contain tasks that have not ended (End)
Storage domains whose refresh status is NotInitialized, Processing, or Failure
You can use the GetTasks command to check the status of tasks.
Details of CLI commands60