HP StorageWorks P9000 Tiered Storage Manager Software 7.1.1 CLI Reference Guide (TB585-96014, September 2011)
Detailed information about MegaTechUSP600-Primary and MegaTechUSP600-Secondary
is output. The error information that begins with List of 1 ErrorInfo elements: is displayed
at the end of the information about MegaTechUSP600-Secondary because refreshStatus
of MegaTechUSP600-Secondary is Failure.
RESPONSE:
List of 2 StorageDomain elements:
An instance of StorageDomain(1 of 2)
name=MegaTechXP12000-Primary
totalCapacityInGB=8,552
usedCapacityInGB=6,576
usedCapacityPercentage=77
freeCapacityInGB=1,975
freeCapacityPercentage=23
numberOfSubsystems=2
numberOfStorageTiers=0
numberOfMigrationGroups=0
refreshStatus=Success
lastRefreshedTime=2011/08/19 21:43:13
controllerSerialNumber=14011
controllerDisplayModel=XP12000
controllerName=XP12000@10.208.151.151
logicalDKCNumber=
description=XP12000-Primary
An instance of StorageDomain(2 of 2)
name=MegaTechXP12000-Secondary
totalCapacityInGB=Unknown
usedCapacityInGB=Unknown
usedCapacityPercentage=Unknown
freeCapacityInGB=Unknown
freeCapacityPercentage=Unknown
numberOfSubsystems=Unknown
numberOfStorageTiers=3
numberOfMigrationGroups=3
refreshStatus=Failure
lastRefreshedTime=
controllerSerialNumber=59432
controllerDisplayModel=XP12000
controllerName=Unknown
logicalDKCNumber=
description=XP12000-Secondary
List of 1 ErrorInfo elements:
An instance of ErrorInfo(1 of 1)
message=KATS62010-E message-contents
ModifyStorageDomain
The ModifyStorageDomain command can be used to change information (the name or description)
for a storage domain.
Note that information cannot be changed for storage domains in the following states:
• Storage domains that contain tasks that have not ended (End)
• Storage domains whose refresh status is NotInitialized, Processing, or Failure
You can use the GetTasks command to check the status of tasks.
Details of CLI commands60