HP StorageWorks P9000 Tiered Storage Manager Software 7.1.1 CLI Reference Guide (TB585-96014, September 2011)

If this command is executed for a storage domain that requires a refresh, a warning message will be
output to the standard error output.
Syntax
htsmcli [ server-location] ModifyStorageDomain
[ common-option ]
[ { -d | --detail } ]
name=storage-domain-name
[ newname=storage-domain-name ]
[ newdescription=description-for-the-storage-domain ]
Options
-d or --detail
Specify this to display detailed information in the standard output after CLI command execution.
If you omit this option, nothing will be displayed in the standard output.
Parameters
Table 15 Parameters of the ModifyStorageDomain command
DetailsParameter
Specify the name of the storage domain whose information you want to change.
name
Specify a new storage domain name.
This name should be unique to Tiered Storage Manager software.
If this is omitted, the name of the storage domain will not change.
[newname]
Specify a new storage domain description.
If this is omitted, the description of the storage domain will not change.
If you specify only spaces, the previous storage domain description will be deleted.
[newdescription]
Legend:
[ ]: Specifying this parameter is optional.
Output items
Table 16 Items output by the ModifyStorageDomain command (StorageDomain instance)
DescriptionItem
The name of the storage domain
name
The serial number of the domain controller
controllerSerial-
Number
The model name displayed on the domain controller
controllerDisplay-
Model
The name of the domain controller
controllerName
CLI Reference Guide 61