HP XP P9000 Command View Advanced Edition Suite Software 7.6.1-00 CLI Reference Guide

differentialManagement=false
snapshotPoolID=-1
journalPoolID=-1
thpType=1
consumedCapacityInKB=10,486,080
thpPoolID=1
threshold=-1
tcaPoolID=-1
thpPoolVolControlFlag=2
managementAreaPoolID=-1
.
. (repeated for other LogicalUnit instances)
.
*****: The values are encoded by the CLI.
GetStorageArray
GetStorageArray obtains information about storage systems managed by the Device Manager
server.
To acquire the information about a specific element or to narrow down the range of information
acquired by specifying conditions, use the parameter subtarget, the subinfo parameters (such as
the parameters arraygroupsubinfo and lusubinfo), and other parameters of the
GetStorageArray command.
Related topics
Appendix B, page 489
Using the GetStorageArray parameter
This section describes how to acquire various information by combining the parameter subtarget
and the subinfo parameters of the GetStorageArray command.
The parameter subtarget:
Use this parameter to acquire more specific information about an element than the basic storage
system-related information that can be obtained by the GetStorageArray command.
NOTE:
When you execute the GetStorageArray command with the subtarget
parameter specified and without the model and serialnum parameters specified,
if a value other than 0 is specified for statusOfDBInconsistency (which is
displayed under An instance of StorageArray as the result of the
GetStorageArray command), information of the component specified for the
subtarget parameter might not be output to the command output. If a value
other than 0 is written for statusOfDBInconsistency, this indicates that the
status of the database is inconsistent. For details about the meaning of the
statusOfDBInconsistency values other than 0, see StorageArray
instance on page 424.
The subinfo parameters:
Command reference132