HP XP P9000 Command View Advanced Edition Suite Software 7.6.1-00 CLI Reference Guide

DescriptionStatusParameter name
Filter used for selecting the LDEV
Available values are OPEN, INTERMEDIATE, and MAINFRAME,
which are not case-sensitive. To specify two or more values,
separate them with semicolons (;). If you omit this parameter, all
LDEVs are displayed. If you specify OPEN, the LDEVs for an open
volume are displayed. If you specify INTERMEDIATE, the LDEVs
for an intermediate volume are displayed. If you specify
MAINFRAME, the LDEVs for a mainframe volume are displayed.
If you specify OPEN;MAINFRAME, the LDEVs for both the open
volume and mainframe volume are displayed.
Optional
ldevfilter
Starting sequence number of logical devices for which information
is to be obtained
Specify this parameter when you want to obtain information for
a part of logical devices in a specific storage system.
When logical device information is ordered by device number
(in ascending order) from 0, specify the first number in the
sequence of logical devices that you want to obtain.
This parameter must be specified together with the
numOfElementsFilter, model, and serialnum parameters.
Optional
startElement-
NumFilter
Number of logical devices for which information is to be obtained
Specify this parameter when you want to obtain information for
a part of logical devices in a specific storage system. Specify the
number of logical devices for which information is to be obtained.
This parameter must be specified together with the
startElementNumFilter, model, and serialnum
parameters.
The maximum recommended value is 16384.
Optional
numOfElements-
Filter
Label name of logical units for which information is to be obtained
Specify this parameter when you want to obtain information about
logical devices for which a specific label is specified. You can
specify only one label.
Optional
label
Tiering policy IDs that have been applied to Smart volumes
Specify this parameter when you want to obtain information about
Smart volumes for which a specific tiering policy has been
applied. You can specify only one tiering policy ID.
For details about the values that can be specified, see the
description of the tieringpolicy parameter in Table 79 .
Optional
(P9500)
tieringpolicy
Parameter values to obtain in advance
serialnum and model
Obtain these values from the execution result of the GetStorageArray command. In the execution
result, use the arrayType value or the displayArrayType value to specify the model para-
meter, and use the serialNumber value to specify the serialnum parameter.
devnum
Obtain this value from the execution result of the GetStorageArray (subtarget=LDEV)
command. Execute this command by specifying only the model and serialnum parameters,
and LDEV for the subtarget parameter. In the execution result of this command, the required
CLI Reference Guide 159