HP XP P9000 Command View Advanced Edition Suite Software 7.6.1-00 CLI Reference Guide

DescriptionStatusParameter name
Nickname of the host storage domain
Specify this parameter to acquire information about a particular
path. When you specify this parameter, you must also specify the
model and serialnum parameters, either the portname or
port parameter and the devnum parameter.
Do not specify this parameter together with the domain
parameter. If they are specified at the same time, an error occurs.
Optional
domainnickname
Domain ID of the host storage domain
Specify this parameter to acquire information about a particular
path. You can specify a decimal or hexadecimal value. When
you specify this parameter, you must also specify the model and
serialnum parameters, either the portname or port
parameter, and the devnum parameter.
Do not specify this parameter together with the domainnickname
parameter. If they are specified at the same time, an error occurs.
Optional
domain
Device number of the logical unit
For P9500 and XP24000/XP20000:
Specify this parameter as a decimal number or colon-delim-
ited hexadecimal number in the format ww:xx:yy, where
ww is the LDKC number, xx is the CU number, and yy is the
LDEV number. ww is optional. If ww is omitted, LDKC is as-
sumed to be 0.
For XP12000/XP10000/SVS200 and XP1024/XP128:
Specify this parameter as a decimal number or colon-delim-
ited hexadecimal number in the format xx:yy, where xx is
the CU number, and yy is the LDEV number.
When you specify this parameter, you must also specify the
model and serialnum parameters, either the portname or
port parameter, and either the domainnickname or domain
parameter.
Optional
devnum
Parameter values to obtain in advance
serialnum and model
Obtain these values from the execution result of the GetStorageArray command. In the execution
result, use the arrayType value or the displayArrayType value to specify the model para-
meter, and use the serialNumber value to specify the serialnum parameter.
objectid
Obtain this value from the execution result of the GetStorageArray (subtarget=Path)
command. Execute this command by specifying only the model and serialnum parameters,
and Path for the subtarget parameter. In the execution result of this command, the required
objectID value appears under An instance of Path. Use this objectID value to specify
the objectid parameter.
Command execution example 1 (when the objectid parameter is not specified)
In this example, the GetStorageArray (subtarget=Path) command obtains information about
paths to a storage system (serial number: 10001, model: XP1024). The information includes information
about the WWNs of these paths and the host.
Command reference174