HP XP P9000 Command View Advanced Edition Suite Software 7.6.1-00 CLI Reference Guide

DescriptionStatusParameter name
Execution cycle of performance monitoring and hardware tier
relocation
This parameter can be specified when automigration is set
to enable.
One of the following values can be specified.
0: 30 minutes
1: 1 hour
2: 2 hours
4: 4 hours
8: 8 hours
24: 24 hours
You can specify 0 only when the microcode version is
70-02-XX-XX/XX or later.
Optional
(P9500)
migrationinter-
val
#1, #5
Start time of performance monitoring
This parameter can be specified when migrationinterval
is set to 24.
Specify a time in the range from 00:00 to 23:59 in HH:MM
format.
Optional
(P9500)
monitorstart-
time
#1, #5, #6
End time of performance monitoring
This parameter can be specified when migrationinterval
is set to 24.
Specify a time in the range from 00:00 to 23:59 in HH:MM
format.
Optional
(P9500)
monitorend-
time
#1, #5, #6
Performance monitoring mode.
This parameter can be specified when tiercontrol is set to
enable.
Specifiable values vary, depending on the microcode version.
If the microcode version is earlier than 70-02-XX-XX/XX:
0: Periodic
If the microcode version is 70-02-XX-XX/XX or later:
0: Periodic
1: Continuous
Optional
(P9500)
monitoring-
mode
#1, #5
CLI Reference Guide 219