HP XP P9000 Command View Advanced Edition Suite Software 7.6.1-00 CLI Reference Guide

thpTier1ConsumedCapacityInKB=0
thpTier2ConsumedCapacityInKB=-1
tieringPolicy=1
tierRelocation=disable
resourcePartitionUnitID=0
*****: The value is encoded by the CLI.
RefreshPerformanceData
RefreshPerformanceData obtains storage system performance information collected by HP
StorageWorks P9000 Performance Advisor Software, and refreshes the Device Manager server
database with the most recent information.
NOTE:
This command can be used only when HP StorageWorks P9000 Performance Advisor Software is
connected to. For details about the environment settings required for connecting to HP StorageWorks
P9000 Performance Advisor Software and obtaining performance information, see the
HP P9000
Command View Advanced Edition Suite Software Administrator Guide
.
Format
When refreshing performance information for a specific storage system:
hdvmcli [URL] RefreshPerformanceData [options]
serialnum=serial-number model=model
When refreshing performance information for all storage systems:
hdvmcli [URL] RefreshPerformanceData [options]
option=all
Parameters
Table 80 RefreshPerformanceData command parameter
DescriptionStatusParameter name
Serial number of the storage system
Optional
#
serialnum
Model of the storage system
Optional
#
model
Parameter used to refresh performance information for all storage
systems
The value you can specify is all, which is not case-sensitive.
Optional
#
option
#
Always specify either the serialnum and model parameters together, or option=all.
Command reference248