HP XP P9000 Command View Advanced Edition Suite Software 7.6.1-00 CLI Reference Guide

Parameter values to obtain in advance
serialnum and model
Obtain these values from the execution result of the GetStorageArray command. In the execution
result, use the arrayType value or the displayArrayType value to specify the model para-
meter, and use the serialNumber value to specify the serialnum parameter.
Command execution example
In this example, the RefreshPerformanceData command refreshes performance information for
a specific storage system.
hdvmcli RefreshPerformanceData -o "D:\logs\RefreshPerformanceData.log"
serialnum=10037 model=R600
Command execution result
RESPONSE:
An instance of PerformanceStatus
arrayType=XP24000
serialNumber=10037
status=SUCCEEDED
RefreshStorageArrays
The RefreshStorageArrays command refreshes the configuration information for all of the storage
systems (including SMI-S enabled storage systems) that are managed by the Device Manager server
to the most recent information.
Execute this command regularly to keep the Device Manager server database up to date. For storage
systems that are managed by Device Manager, configuration information that is created or modified
from the Remote Console, Remote Web Console, or RAID Manager is added to or updated in the
Device Manager server database each time this command is executed.
NOTE:
To specify a storage system and then refresh its configuration information, use the AddStorageArray
command. When the storage system already exists, the AddStorageArray command performs a
re-discovery operation on the storage system and refreshes the registered information on the Device
Manager server database.
CLI Reference Guide 249