HP XP P9000 Command View Advanced Edition Suite Software 7.6.1-00 CLI Reference Guide

DescriptionAttribute
Type of the drive
If the storage system is P9500 and a THP pool is used, one of the following values
is output:
1: SATA
4: SAS
5: SSD or FMD
-1: If any of the following conditions are satisfied
The drive type is unknown
Drive drive types are mixed (except for SSD and FMD)
Drives with different drive speeds are mixed
This information is invalid for other cases (-1 is output).
diskType
Indicates whether the pool is a Smart pool.
enable: Smart pool
disable: THP pool
tierControl
Indicates whether the automatic execution of performance monitoring and hardware
tier relocation is enabled.
This attribute is valid only when the storage system is P9500 and a Smart pool is
used.
enable
disable
autoMigration
Execution cycle of performance monitoring and hardware tier relocation
0: 30 minutes
1: 1 hour
2: 2 hours
4: 4 hours
8: 8 hours
24: 24 hours
migrationInterval
#1
Start time of performance monitoring (example: 00:00)
This attribute is valid only when migrationInterval is 24.
monitorStartTime
#1
End time of performance monitoring (example: 23:59)
This attribute is enabled only when migrationInterval is 24.
monitorEndTime
#1
Performance monitoring mode
0: Periodic
1: Continuous
monitoringMode
#1
Indicates whether a THP/Smart pool can be configured by mixing internal and
external volumes.
enable
disable
externalMixCompat-
ible