HP XP P9000 Command View Advanced Edition Suite Software 7.6.1-00 CLI Reference Guide

DescriptionStatusParameter name
Emulation type of the logical unit
The following are the specifiable emulation types:
OPEN-3
OPEN-8
OPEN-9
OPEN-E
OPEN-K
OPEN-V
Specify the same emulation type as the parity group in which a
logical unit is created.
If no such emulation is present, parity group emulation is used.
This parameter must be specified if the creationoption
parameter is specified. In this case, OPEN-V is the only value you
can specify.
If you specify the creationoption parameter, OPEN-V is the
only value that you can specify for emulation. In addition, if
you specify the creationoption parameter and omit this
parameter, OPEN-V is set.
Optional
emulation
LU device number
For P9500 and XP24000/XP20000:
Specify this parameter as a decimal number or colon-delim-
ited hexadecimal number in the format ww:xx:yy, where
ww is the LDKC number, xx is the CU number, and yy is the
LDEV number. ww is optional. If ww is omitted, LDKC is as-
sumed to be 0.
For XP12000/XP10000/SVS200 and XP1024/XP128:
Specify this parameter as a decimal number or colon-delim-
ited hexadecimal number in the format xx:yy, where xx is
the CU number, and yy is the LDEV number.
If omitted, the number is automatically generated.
The execution results are output in decimal.
Optional
devnum
If set to LDEV, return the information on LDEV(s) related to the LU.
The value you can specify is LDEV only, which is not
case-sensitive.
Optional
lusubinfo
Format status of LDEVs that constitute an LU
You can specify the following values:
none: Creates an unformatted LDEV.
normal: Creates a formatted LDEV.
quick: Creates an LDEV formatted by using Quick Format.
If omitted, a formatted LDEV is created.
If you specify this value, make sure that the value of the
autoFormatLU attribute of the StorageArray instance is 0.
You can specify quick only for P9500 and XP24000/XP20000
whose microcode version is 60-02-4 X-XX/XX or later.
Optional
(P9500
XP24000
XP20000
XP12000
XP10000
SVS200)
format
Command reference72