HP XP P9000 Command View Advanced Edition Suite Software 7.6.1-02 Release Notes (TB581-96399, March 2014)

CLI copy pair operation error 6119
A CLI copy pair operation may generate the error code 6119. If this occurs, check the following items.
Check the version of RAID Manager or RAID Manager XP that supports the required operation.
Check that RAID Manager or RAID Manager XP is properly installed.
If this does not solve the problem, collect maintenance information and contact HP Technical Support.
KAIC16902-E message with no summary information in the main window during any
operation in the GUI
During any operation in the GUI, the KAIC16902-E message appears in the top window and the
Summary information does not appear in the main window.
If this occurs, close the error dialog box and continue the operation. If you need the summary
information, log in to Device Manager again.
Number of external paths
When the external volume is being directly assigned to the host from the external storage system, the
number of external paths appearing on the external volume tab of the storage system does not match
the number of external paths displayed in Remote Web Console.
Check the number of external paths in Path Information in the Detailed Information window.
Mapping of Available External Volumes
In the GUI, the Available External Volumes created with one of the following volumes cannot be
mapped to Internal Volumes.
Volumes created when the volume virtualization task in the GUI did not succeed by interception.
Volumes in the external storage system allocated to the internal storage system by the CLI AddLun
command.
Volumes in the external storage system allocated to the internal storage system by Element Manager,
XP P9000 Remote Web Console, or XP Remote Web Console.
To map the above volumes, use either of the following:
The CLI AddExternalArrayGroup command
Element Manager, XP P9000 Remote Web Console, or XP Remote Web Console
Clicking a link in the GUI
When clicking a link in the GUI, do not click the link while pressing the Ctrl key.
KAIC16009-E error dialog boxes may appear if you click a link while pressing the Ctrl key.
If this occurs, close all of the error dialog boxes.
Using a Device Manager agent on an AIX host
To use a Device Manager agent on an AIX host, the ODMDIR environment variable must be set in
advance.
Managing path groups with External Storage in XP24000/XP20000 and XP P9500
If you change path group settings using XP P9000 Remote Web Console or XP Remote Web Console,
Device Manager cannot correctly manage the priority of the paths connecting storage systems in their
path group. As a result the following symptoms occur in volume virtualization using the path group
whose settings were changed using Remote Web Console.
Symptom 1 (GUI):
30 Important considerations