Capacity information in the Plan Confirmation window of Plug-in for Virtualization Server
Provisioning
When a user executes an addstorage operation specifying a capacity that includes a value below
the decimal point, the capacity information in the Plan Confirmation window might be different from
the capacity specified by the user.
However, the value entered by the user appears in VMware vSphere Client.
Volume allocation processing in Plug-in for Virtualization Server Provisioning
The volume capacity that can be allocated at one time in Plug-in for Virtualization Server Provisioning
must be less than 2 TB.
The number of resources that can be managed by Plug-in for Virtualization Server
Provisioning
The number of resources that can be managed by Plug-in for Virtualization Server Provisioning is based
on the number of resources that can be managed by Device Manager.
Use a configuration whose number of resources does not exceed the number that Device Manager
can manage.
Script error in Plug-in for Virtualization Server Provisioning
If Flash Player 10.1 or 10.2 is used, a script error might occur.
If this occurs, Device Manager and VMware vCenter Server continue to function normally. Close the
script error dialog box and continue operations.
Displaying the Plug-in for Virtualization Server Provisioning hosts for the first time
When VMware vCenter Server 4.1 is used, it might take some time to display the hosts for the first
time after logging in.
Wait several minutes because Device Manager information is synchronizing with VMware vCenter
Server information.
KAIC07661-E error in Plug-in for Virtualization Server Provisioning
When the Add Storage operation is performed, if the KAIC07661-E error occurs and the VMware
vSphere API name embedded in the message is QueryVmfsDatastoreCreateOptions, the
condition of volumes might be invalid.
Change the specified condition of the Add Storage operation or ask the Storage Administrator to
delete the volumes and create a new volume.
KAIC07663-E in Plug-in for Virtualization Server Provisioning
When the Add Storage operation is performed, the KAIC07663-E message might occur if you
attempt to allocate a beyond the maximum number of recognizable storage devices by the VMware
ESX Server.
Confirm the maximum number of recognizable storage devices by the VMware ESX Server, and then,
after unallocating the volumes from the VMware ESX Server, perform the Add Storage operation
again.