HP XP P9000 Command View Advanced Edition Suite Software 7.6.1-02 Release Notes (TB581-96399, March 2014)

179(bgp)
389(ldap)
465(smtp+ssl)
512(print / exec)
513(login)
514(shell)
515(printer)
526(tempo)
530(courier)
531(chat)
532(netnews)
540(uucp)
556(remotefs)
563(nntp+ssl)
587(smtp)
601(syslog)
636(ldap+ssl)
993(ldap+ssl)
995(pop3+ssl)
2049(nfs)
4045(lockd)
6000(x11)
GUI operations after upgrading Device Manager
After upgrading Device Manager, reboot the browser used as the GUI or clear a cache of the browser,
and log into Command View Advanced Edition Suite products.
If the above operation is not performed, the GUI might be inoperative.
Screen appearance
The information might not appear on the screen or the screen might be frozen. If this occurs, refresh
the screen or log in again.
The task details dialog box for starting monitoring, stopping monitoring, starting
relocation, and stopping relocation
The KAIC06400-E error of a storage system might occur in the message column of the pool selected
in the Task detail dialog box.
Check the monitoring status or relocation status of the pool in the pool list.
Editing tiering policy
The KAIC15017-E error occurs incorrectly when the tiering policies for reserved THP volumes are
edited.
If this occurs, check the status of the THP volumes.