HP XP P9000 Command View Advanced Edition Suite Software 7.6.1-02 Release Notes (TB581-96399, March 2014)

exceed a fixed range. Therefore, check the range in which the Windows Time service can gradually
adjust the time, and then set the frequency of the time adjustments for the Windows Time service so
that the difference between the computer time and the actual time does not exceed that range.
If you cannot use functionality that adjusts the time automatically, or if you need to change the time
immediately, perform the following procedure to change the time manually:
1. Stop the services of Common Component and all Command View Advanced Edition Suite products.
2. To set the clock back, wait until the actual clock time catches up to the computer clock time, and
then restart the computer.
When using the Device Manager server in a time zone within the United States or Canada, set the
operating system of the computer on which the Device Manager server will be installed so that the
operating system is compatible with the new Daylight Saving Time (DST) rules. If the operating system
is not compatible with the new DST rules, the Device Manager server will not be compatible with the
new rules either.
Firewall functions (Windows)
Some of the firewall functions of the operating system might block socket connections on the local host.
You cannot install and operate Command View Advanced Edition Suite products in an environment
in which socket connections are blocked on the local host. When setting up a firewall in the operating
system, configure the settings so that socket connections are not blocked on the local host.
TMP environment variable (Windows)
If multi-byte characters are included in a Windows login account name, they will also be included in
the path specified in the TMP environment variable, and you will not be able to install the Command
View Advanced Edition Suite. Specify a path that does not contain multi-byte characters for the TMP
environment variable before performing an installation.
Terminal service (Windows)
You cannot execute the Command View Advanced Edition Suite installer as a RemoteApp in the
terminal service of Windows Server 2008 or Windows Server 2008 R2.
Symbolic links (Linux)
Ensure that the symbolic links indicated in the following table are not set. If any are set, installation
might not be successful.
LocationSymbolic link destination
/optFile system for installation
/var/optLog output directory
/var/tmpTemporary directory
Under /opt/CVXPAE
5
Installation directory for the Device Manager server and any
directories under the installation directory
Under /var/opt/CVXPAE
5
Installation directory for Command View Advanced Edition
Suite products and any directories under the installation
directory
Under /var/opt/CVXPAE /database
5
Installation directory for the Common Component database
and any directories under the installation directory
Under /var/opt/CVXPAE /database/Base
5
Under /var/opt/CVXPAE/database/DeviceManager
5
Installation directory for the Device Manager server database
and any directories under the installation directory
Important considerations 49