HP XP P9000 Performance Advisor Software v5.5 User Guide (T1789-96337, Februrary 2013)

Figure 15 THP Pool Screen
IMPORTANT: The data on the Smart pools and the ThP pools are not displayed if the pools are
not configured in the selected P9000 disk array. The following error message is displayed: Smart
and ThP pools are not configured for this P9500 Disk Array.
“Pool Information screen details” (page 196) describes the Pool Information screen elements:
Table 11 Pool Information screen details
DescriptionTable name
Displays the configuration and performance data of the Smart
and the ThP pools. The data includes the following:
Pool Information
Pool ID, type, and the pool status
I/O per second data, MB/second data throughput, and
backend transfers between the cache and the drives
For more information, see “Pool Information table” (page 197).
Based on whether you select a Smart pool or a ThP pool, the
following details are displayed:
Pool <Pool ID> Details
The performance data of the VVols for the Smart pool or the
ThP pool. The performance data includes the I/O per second
data, MB/second data throughput, backend transfers, and
the average read and write response time values of the VVols.
The utilization data for the respective RAID groups and the
pool LDEVs.
In addition, the following details are displayed only for a Smart
pool:
The total and the used capacity
The capacity threshold value
For more information, see “Pool Details table” (page 198).
Click Refresh Pool Info and Details to view the latest data for the Smart pools and the ThP pools.
Viewing Smart pool monitoring details
Click a pool in the pool information table to see the monitoring details of a particular pool.
196 Viewing XP and P9000 disk array components