HP XP P9000 Performance Advisor Software v5.5 User Guide (T1789-96337, Februrary 2013)

What happens...Automatic updatesScenarios
is already enabled to receive automatic
updates.
Hence, you must edit the schedule
manually to add or remove components
from Schedule 2. However, if Schedule
1 is not enabled for automatic updates,
you can still enable Schedule 2 to
receive automatic updates.
The newly discovered RAID groups and
ports are neither added to Schedule 1
Both Schedule 1 or Schedule 2 are
disabled to receive automatic updates.
Two schedules created (Schedule 1
and Schedule 2)
or Schedule 2. Hence, you must edit
the schedules manually to add or
remove components in the existing list.
Example use cases
Scenario 1
While creating a performance data collection schedule:
1. The RAID groups and ports are not selected from the respective component type lists.
2. Instead, the ThP, snapshot, continuous access journal volumes, or the external RAID groups
are selected from the respective component type lists.
3. The Add new RAID Groups, Ports to this schedule check box is selected.
After the settings are saved, the following changes occur:
Only the newly discovered RAID groups and ports are automatically added to this performance
data collection schedule, as the Add new RAID Groups, Ports to this schedule check box is
selected.
The new virtual volumes are also automatically added to this schedule, as it is already collecting
the performance data for virtual volumes.
The RAID groups and ports that were not selected from the respective component type lists
are automatically added to the second schedule when it is created. If a second schedule is
not created, the existing list of RAID groups and ports are still available for selection in the
first schedule. You must modify the first schedule if you want to add these components to the
existing list. For more information on editing a performance data collection schedule, see
“Editing frequency of performance data collection” (page 68).
Scenario 2
While creating a performance data collection schedule:
1. The ThP, snapshot, continuous access journal volumes, or the external RAID groups are not
selected from the respective component type lists.
2. The Add new RAID Groups, Ports to this schedule check box is selected.
After the settings are saved, the following changes occur:
Only the newly discovered RAID groups and ports are automatically added to this performance
data collection schedule, as the Add new RAID Groups, Ports to this schedule check box is
selected.
The new virtual volumes are not added to this schedule, as it is not collecting the performance
data for virtual volumes.
The RAID groups, ports, and the virtual volumes that were not selected from the respective
component type lists are automatically added to the second schedule when it is created.
66 Collecting configuration and performance data