HP XP P9000 Performance Advisor Software v6.0 Command-line User Interface Reference Guide

Displays data in a readable format.–hr
Specify the address of a management station in the format <http://
path.to.managementstation:<port>> or <https://
path.to.managementstation>.
–ms <URL>
Specify a user name and password pair in the format user name:password.–auth <user:passwd>
Specify the version number. Indicates how the data must be displayed. Currently supported
values are 010500 and 010600. The default value is 010500.
–dver <xxxxxx>
Required. Specify the logical device number in the form <cu>:<ldev>, where:
<cu> is the control unit number (0...ff).
–ldev <logical device #>
<ldev> is the logical device number (0...ff).
NOTE: To get the logical device number, run the LUND command. For more information,
see LUND .
Specify the start time in the format mm.dd.yyyy hh:mm:ss.–st <start time>
Specify the end time in the format mm.dd.yyyy hh:mm:ss.–et <end time>
Prints the usage statement.–?
Examples
ldev -dkc 30143 -ldev 1:6C -st 01.03.2001 12:49:00 -et 01.03.2001
14:20:00
ldev -dkc 10055 -ldev 0:7E
ldev -dkc 10055 -L -ldev 0:7E
ldev -dkc 10055 -hr -ldev 0:7E -dver
ldev -dkc 10055 -ldev 0:7E -dver 010600
ldev -dkc 10055 -ldev 0:7E -dver 010600 L
ldev -dkc 10055 -ldev 0:7E -st 06.19.2006 14:00:00 -et 06.19.2006
14:30:00
ALARMHIST
Syntax
alarmhist [-d<delim>] [-L] [-hr] [-ms <URL>] [-auth <user:passwd>] [-dkc
<serial #>]
[-metric <Category>] [-mval <Item Value>] [-st <mm.dd.yyyy hh:mm:ss>]
[-et <mm.dd.yyyy hh:mm:ss>] [-tclass <Time Class>] [-pf <password file>]
Supported disk array types
XP and P9000 disk arrays
Description
Displays the alarm history data. Alarm history objects are created when the array usage exceeds
a certain user-defined threshold in one of the metric categories. This command does not display
the status of alarm.
Switches
Specify the address of a management station in the format
<http://path.to.managementstation/>.
–ms <URL>
Specify a user name and password pair in the format username:password.–auth <user:passwd>
Specify the array serial number.–dkc <serial #>
Specify the metric category. Valid values are as follows:
nl
–metric <Category>
IO_TOTAL - LDEV IO Total
nl
ALARMHIST 23