Hitachi Dynamic Link Manager Software Users Guide for Linux

Examining the Messages
Examine the message that is output to syslog in the host by using
applications or tools for monitoring messages. If the KAPL08022-E message
is output, view the message to check the path in which the error has
occurred. For details on each item displayed in messages, see Checking Error
Information in Messages on page 5-2.
Obtain Path Information
Obtain path information.
Execute the following command:
# /opt/DynamicLinkManager/bin/dlnkmgr view -path -iem -hbaportwwn >
pathinfo.txt
pathinfo.txt is the redirection-output file name. Use a file name that
matches your environment.
Identifying the Error Path
Check the obtained path information to find the path with the error. In the
Status column, the error path has the status Offline(E) or Online(E).
Narrowing Down the Hardware That Might Have Caused the Error
Check the DskName, iLU, ChaPort, and HBAPortWWN columns of the path with
the error to narrow down the hardware that may be the cause of the error.
To physically identify the hardware corresponding to DskName, iLU, and
ChaPort, use the information provided by the storage-system management
program.
Identifying the Error Location and Correcting any Hardware Error
Use the Windows and hardware management tools to identify the error
location, and then resolve the problem. For hardware maintenance, contact
your hardware vendor or maintenance company, if there is a maintenance
contract.
Placing the Path Online
After the path has recovered from the error, use the dlnkmgr command's
online operation to place the path back online. For details on the online
operation, see
online (Places Paths Online) on page 6-10. Execute the
following command:
# /opt/DynamicLinkManager/bin/dlnkmgr online
Executing this command places all the offline paths online.
Troubleshooting
5-5
Hitachi Dynamic Link Manager (for Linux®) User Guide