Hitachi Dynamic Link Manager Software Users Guide for Linux

Message ID Message Text Explanation
And if the error message is
outputted before this message,
remove the cause of the error with
reference to the contents of the
message.
cp:
Confirm that there is enough
unused capacity and that the
user has write permission in the
root directory (/).
dlmcfgmgr:
Confirm that the version of
the OS has not changed
since you made the initial
ramdisk image file.
Take action according to
the contents output in the
log of the dlmcfgmgr utility.
Confirm that the user has
write permission in the root
directory (/).
dlnkmgr:
Confirm that HDLM has
been configured.
Take action according to
the contents output in the
log of the dlmcfgmgr utility.
Confirm that the user has
write permission in the root
directory (/).
mkdir:
Confirm that there is enough
unused capacity and that the
user has write permission in the
following directory:
/etc/opt/
DynamicLinkManager.
/opt/DynamicLinkManager.
The root directory (/)
mount:
Confirm that there is unused
capacity in the loop device.
umount:
A temporary file remains, so do
the following:
1. Unmount
/etc/opt/
DynamicLinkManager/tmp/
Messages
8-119
Hitachi Dynamic Link Manager (for Linux®) User Guide