HP XP7 Continuous Access Synchronous User Guide (TK911-96004)

2. To check path and port information, from the Storage Systems tree, click Replication > Remote
Connections > Connections (To).
Check connections under View Port Condition.
Check Status and other details in the Connections (To) tab.
Remote path status definitions
The following table provides remote path status descriptions.
DefinitionStatus
This path has been successfully established and can be used for Continuous Access
Synchronous remote copy activities.
Normal
The link initialization procedure with the secondary system has failed, because the physical
path connection between either the primary and secondary system, or between the primary
system and the host, was missing.
Initialization Failed
A timeout error has occurred between the primary and secondary system.Communication Timeout
The remote path link function has been rejected by the secondary system. All remote path
resources in the secondary system might be used for other connections.
Path Rejected
The serial number of the control unit that is connected to this remote path does not match
the serial number specified by the Add Remote Connection window.
Serial Number Mismatch
The specified port does not have the initiator attribute.Invalid Port Mode
There are three possible causes:RCU Port Number
Mismatch
The specified port in the secondary system is physically disconnected from the primary
system.
The port is not configured as an RCU target port.
The specified port number is not available.
The microcode on the remote side does not support the fibre remote copy function; or the
specified port type is not RCU target.
RCU Port Type Mismatch
A timeout error has occurred on the path between the primary and secondary system.Communication Failed
This remote path was blockaded because a path error or a link error occurred continuously.Logical Blockade
68 Monitoring and maintaining the Cnt Ac-S system