HP XP7 Continuous Access Synchronous User Guide (TK911-96004)

Where:
* is the instance number.
HOST is the host name.
Example:
Error codes appear on the right of the equal symbol (=).
Review RAID Manager error codes in the following topics.
“SSB2 error codes when SSB1 = 2E31/B901/B90A/B90B/B912/D004” (page 83)
“SSB2=B992 error codes when SSB1 = B901 or B90A” (page 91)
SSB2 error codes when SSB1 = 2E31/B901/B90A/B90B/B912/D004
DescriptionError code
(SSB2)
The pair cannot be created because the specified P-VOL belongs to a different CLPR than the registered
consistency group CLPR.
4A96
A pair cannot be resynchronized because the specified consistency group does not have the Open/MF
attribute.
4B02
The pair operation was rejected because the necessary shared memory is not mounted in the primary system.4BE0
The command cannot be executed because the user authentication is not performed.9100
The pair cannot be created because the system identifier is not correct (left-most number in the 6-digit serial
number).
B920
The consistency group Paircreate or Pairresync was rejected because supported and unsupported microcodes
are used in the DKC.
B923
You cannot run the following operations to a pair in a 2DC configuration:B927
Swap Suspend
Takeover
The pair cannot be created because the Mirror ID is invalid.B928
The pair operation was rejected because the online microcode is being replaced.B929
The pair cannot be created because the specified volume is a command device.B92A
The pair cannot be created because Cnt Ac-S is not installed.B934
S-VOL hide mode is not supported.B935
The required shared memory for operating Continuous Access Synchronous is not installed.B936
The specified volume is a P-VOL. The pair cannot be released because the P-VOL is specified as an S-VOL.B93B
The specified volume is an S-VOL. The pair cannot be released because the S-VOL is specified as a P-VOL.B941
The command was rejected because the volume is unpaired.B945
The specified LU is not defined. The DKC configuration might have been changed. Restart RAID Manager.B952
The operation cannot run because pair status is either PSUS (by user) or PSUE (because of failure).B97B
The command was rejected because the volume is unpaired.B97C
Troubleshooting using RAID Manager 83