HP XP7 Continuous Access Synchronous User Guide (TK911-96004)

DescriptionError code
(SSB2)
The pair cannot be created because the consistency group number is greater than is allowed.B990
If this error occurred when you did not specify the consistency group number, Contact HP for assistance.
The Swap Resync operation cannot be performed because the S-VOL is not in PSUS or SSWS status. (Swap
Resync resynchronizes differential data when the S-VOL is swapped for the P-VOL.)
B994
The pair cannot be created because the secondary system path setting is invalid.B998
The pair cannot be created because Cnt Ac-S Asynchronous is not supported.B99B
The DKC LDEV configuration might have been changed while starting RAID Manager. Restart RAID Manager.B9BD
The source of the command device has run out. In LUN Manager, set the command device to OFF, then to
ON.
B9C0
The pair cannot be resynchronized because the pair was not in the Suspend status.C162
The pair cannot be created because the S-VOL is not available.C16B
A request for a Pairsplit-S operation was rejected because the status change of the S-VOL failed.C184
A request for a Pairsplit-S operation was rejected because the pair status was invalid.C189
A request for a Pairsplit-S operation was rejected because the corresponding volume or group was changing
status.
C18A
The pair cannot be split because the S-VOL pair status was in transition.C194
A request for a Pairsplit-r operation was rejected because the pair status was already PSUS (by user) PSUS
(because of failure).
C195
Pair split cannot run because the group includes no pair that can be split.C198
A request for a Pairsplit-r operation was rejected because the corresponding volume or group was changing
status.
C199
The pair's status cannot be changed during the power-on processing of the DKC.C1BE
The command was rejected because it was issued to a non-Cnt Ac-S volume.C1D6
The command was rejected because the specified volume is a P-VOL. If the error occurs when the volume
is unpaired, select the volume in Remote Web Console, release the pair using the Yes option for Delete Pair
by Force in the Pairsplit-S dialog box, and then run the command again.
C211
The command was rejected because the specified volume is an S-VOL. If the error occurs when the volume
is unpaired, select the volume in Remote Web Console, release the pair using the Force Delete Pairs window,
and then run the command again.
C212
The command was rejected because the secondary system is not registered, or the registered information
is invalid.
C214
The command was rejected because an internal logical error has occurred.C215
The command was rejected because the pair status is invalid.C218
The command was rejected because the P-VOL status is other than PSUS (by user) PSUS (because of failure).C21A
The command was rejected because the secondary system is not registered, or the registered information
is invalid.
C21C
The command was rejected because the pair release was run on a volume other than P-VOL.C22A
The command was rejected because the volume is unpaired.C22C
The command was rejected because the specified volume is the volume other than the P-VOL.C22D
The command was rejected because the pairsplit command specifying -P option (write protection of P-VOL)
was issued to a volume whose status is not PAIR.
C22E
84 Troubleshooting