HP XP7 Continuous Access Synchronous User Guide (TK911-96004)

DescriptionError code
(SSB2)
The P-VOL is a device not supported by Cnt Ac-S.C3A0
The SSID or CU number of the secondary system is invalid.C3A6
The device type combination between the P-VOL and S-VOL is invalid.C3A8
The secondary system's cache is blocked on one side.C3AA
The secondary system's cache is blocked on one side.C3AB
Cnt Ac-S is not supported for this controller emulation type of the secondary system.C3AC
The secondary system capacity exceeds the license capacity.C3AD
Cnt Ac-S is not installed on the secondary system.C3AE
The DKC type of the secondary system is not supported by Cnt Ac-S.C3AF
The number of paths is smaller than the required minimum number of paths.C3B1
An internal error occurred.C3B3
The configuration combination of P-VOL and S-VOL is invalidC3B5
The P-VOL is an BC volume.C3B6
The S-VOL is an BC volume.C3B7
An internal error occurred.C3B8
The specified S-VOL LUN is not defined; or the LUN includes a CU LDEV that is not supported by the primary
system.
C3B9
A request for a Paircreate operation was rejected because of one of the following reasons:C3BA
The secondary system's SSID or CU number is not supported.
Though the secondary system's SSID or CU number is supported, the microcode of the main system device
does not support them.
Cnt Ac-S is not installed on the secondary system.C3BC
These volumes cannot be specified as a Cnt Ac-S S-VOL:C3BE
BC S-VOL not in PSUS status
BC reserved volume
BC P-VOL in the process of reverse copy
A Cnt Ac-S S-VOL cannot be specified as an BC S-VOL, reserved volume, or P-VOL in the process of reverse
copy.
C3BF
A request for a Paircreate operation was rejected because the specified volume was already part of a Cnt
Ac-S or Cnt Ac-J pair (including journal volumes).
C3C7
The S-VOL is reserved; or a secondary system, S-VOL, or the path between primary system and secondary
system is in the BUSY status.
C3CA
The S-VOL is an BC volume.C3CD
The DKC type of the secondary system is not supported by Cnt Ac-S.C3D2
A pair cannot be created because the P-VOL is being used by Auto LUN.C3D4
The specified S-VOL is unavailable because the connecting port cannot recognize it.C3D6
The pair status of the S-VOL is invalid.C3D7
The pair cannot be created because the volume specified for the S-VOL is a system volume.C3D8
The pair cannot be created if the Cnt Ac-S S-VOL corresponds to any of the following:C3D9
88 Troubleshooting