HP P9000 Command View Advanced Edition Suite Software 7.2 CLI Reference Guide

DescriptionStatusParameter name
Parity group name
The following value specification formats can be used:
n
n - n
n - n - n
E n - n
V n -1
X n -1
Here, n is an integer of 1 or greater, while E, V, and X are fixed.
If this parameter is specified, the model parameter must also be
specified.
Optional
arraygroupname
Parameter values to obtain in advance
serialnum and model
Obtain these values from the execution result of the GetStorageArray command. In the execution
result, use the arrayType value or the displayArrayType value to specify the model para-
meter, and use the serialNumber value to specify the serialnum parameter.
Command execution example 1
In this example, the GetStorageArray (subtarget=ArrayGroup) command obtains information
about parity groups in a storage system (serial number: 14010, model: XP12000).
hdvmcli GetStorageArray -o "D:\logs\GetStorageArray_ArrayGroup.log"
subtarget=ArrayGroup model=XP12000 serialnum=14010
Command execution result 1
RESPONSE:
An instance of StorageArray
.
. (Attributes of StorageArray are omitted here)
.
List of 20 ArrayGroup elements:
An instance of ArrayGroup
objectID=*****
chassis=1
number=0
displayName=1-1-1
raidType=RAID5(3D+1P)
emulation=OPEN-3
diskType=DKR2E-J146FC
diskSize=146
diskSizeInKB=153,092,096
formFactor=-1
controllerID=1
totalCapacity=418,184,640
CLI Reference Guide 121