HP P9000 Command View Advanced Edition Suite Software 7.2 CLI Reference Guide

Command execution example
In this example, the GetStorageArray (subtarget=Component) command obtains information
about the configuration of a storage system (serial number: 10007, model: XP24000).
hdvmcli GetStorageArray -o "D:\logs\GetStorageArray_Component.log"
subtarget=Component model=XP24000 serialnum=10007
Command execution result
RESPONSE:
An instance of StorageArray
objectID=*****
name=R600@10.208.115.220
description=R600 (10007) at 10.208.115.220
serialNumber=10007
arrayFamily=XP24K/20K
arrayType=XP24000
microcodeVersion=60-06-20/00
agentVersion=05_06_00
productName=RAID600
controllerVersion=60-06-21-00/00
numberOfControllers=2
capacityInGB=6,617
cacheInMB=65,536
sharedMemoryInMB=-1
numberOfSpareDrives=-1
freeCapacityInGB=3,765
allocatedCapacityInGB=2,851
autoLunCapacityInGB=0
onDemandCapacityInGB=0
totalFreeSpaceInGB=3,438
largestFreeSpaceInGB=466
capacityInKB=6,938,910,203
freeCapacityInKB=3,948,652,130
allocatedCapacityInKB=2,990,258,073
autoLunCapacityInKB=0
onDemandCapacityInKB=0
totalFreeSpaceInKB=3,605,150,982
largestFreeSpaceInKB=489,664,512
multipathSupport=1
securityStatus=2
sequenceNumber=10007
displayArrayFamily=R600
displayArrayType=R600
numberOfLUs=3,412
numberOfAllocatedLUs=1,739
numberOfUnallocatedLUs=1,671
slprStatus=0
openTotalCapacity=6,520,600,283
openAllocatedCapacity=2,990,258,073
openFreeCapacity=3,530,342,210
openAutoLunCapacity=0
openOnDemandCapacity=0
imTotalCapacity=0
imAllocatedCapacity=0
Command reference126