HP P9000 Command View Advanced Edition Suite Software 7.2 CLI Reference Guide

type=12
.
. (repeated for other PortController instances)
.
*****: The value is encoded by the CLI.
Command execution example 2
In this example, the GetStorageArray (subtarget=PortController) command obtains
information about a port controller (controller ID: 1) used for a storage system (serial number: 10001,
model: XP1024).
hdvmcli GetStorageArray -o "D:\logs\GetStorageArray_PortController.log"
subtarget=PortController model=XP1024 serialnum=10001 controllernum=1
Command execution result 2
RESPONSE:
An instance of StorageArray
.
. (Attributes of StorageArray are omitted here)
.
List of 1 PortController elements:
An instance of PortController
objectID=*****
cluster=1
card=1
controllerID=1
displayName=CHA-1P
mode=1
type=12
*****: The value is encoded by the CLI.
GetStorageArray (subtarget=ReplicationInfo)
GetStorageArray (subtarget=ReplicationInfo) obtains information about copy pairs.
NOTE:
For XP24000/XP20000 and XP12000/XP10000/SVS200, the partitioned storage administrator
cannot obtain all the information about paired volumes and external volumes.
For XP24000/XP20000, if there is information about copy pairs consisting of mainframe volumes,
microcode version 60-01-6X-XX/XX or later is required. When using an older microcode version
and obtaining copy pair information, the information about copy pairs consisting of mainframe
volumes is output as the information about copy pairs consisting of open volumes.
Command reference170