HP P9000 Command View Advanced Edition Suite Software 7.2 CLI Reference Guide

Parameters
Table 65 ModifyArrayReservation command parameters
DescriptionStatusParameter name
Serial number of the storage systemRequired
serialnum
Model of the storage systemRequired
model
Parameter values to obtain in advance
serialnum and model
Obtain these values from the execution result of the GetStorageArray command. In the execution
result, use the arrayType value or the displayArrayType value to specify the model para-
meter, and use the serialNumber value to specify the serialnum parameter.
Command execution example
hdvmcli ModifyArrayReservation -o "D:\logs\ModifyArrayReservation.log"
"model=XP12000" "serialnum=14009"
Command execution result
An instance of ArrayReservation
objectID=*****
target=*****
serialNumber=14009
arrayType=XP12000
loginID=dmuser
beginTime=1,039,003,476
*****: The values are encoded by the CLI.
ModifyLabel
ModifyLabel modifies the label of a logical unit.
Parameters
Table 66 ModifyLabel command parameters
DescriptionStatusParameter name
Serial number of the storage systemRequired
serialnum
Model of the storage systemRequired
model
Command reference178