HP P9000 Command View Advanced Edition Suite Software 7.2 CLI Reference Guide

Command execution result 1
RESPONSE:
An instance of StorageArray
.
. (Attributes of StorageArray are omitted here)
.
List of 1 Lu elements:
An instance of LogicalUnit
objectID=*****
devNum=12,288
displayName=00:30:00
emulation=OPEN-V
devCount=1
devType=
capacityInKB=209,715,200
path=false
commandDevice=false
commandDeviceEx=0
commandDeviceSecurity=false
chassis=16,485
arrayGroup=199
arrayGroupName=X200-1
raidType=Unknown
currentPortController=-1
defaultPortController=-1
isComposite=0
continuousAccessVolumeType=Simplex
businessCopyVolumeType=Simplex
snapshotVolumeType=Simplex
journalVolumeType=Simplex
sysVolFlag=0
externalVolume=0
differentialManagement=false
snapshotPoolID=-1
journalPoolID=-1
thpType=0
consumedCapacityInKB=0
thpPoolID=0
threshold=15
tcaPoolID=-1
thpPoolVolControlFlag=-1
*****: The value is encoded by the CLI.
Command execution example 2
In this example, the ModifyVirtualVolume command changes the tiering policy for volumes for
Smart Tiers to level 1.
hdvmcli ModifyVirtualVolume -o "D:\logs\ModifyVirtualVolume.log"
model=P9500 serialnum=15000 devnums=00:00:C4 tieringpolicy=1
Command reference202