HP P9000 Command View Advanced Edition Suite Software 7.2 CLI Reference Guide

Command execution example
In this example, the RefreshPerformanceData command refreshes performance information for
a specific storage system.
hdvmcli RefreshPerformanceData -o "D:\logs\RefreshPerformanceData.log"
serialnum=10037 model=R600
Command execution result
RESPONSE:
An instance of PerformanceStatus
arrayType=XP24000
serialNumber=10037
status=SUCCEEDED
RefreshStorageArrays
The RefreshStorageArrays command refreshes the configuration information for all of the storage
systems (including SMI-S Enabled storage systems) that are managed by the Device Manager server
to the most recent information.
Execute this command regularly to keep the Device Manager server database up to date. For storage
systems that are managed by Device Manager, configuration information that is created or modified
from the Remote Console, Remote Web Console, or RAID Manager is added to or updated in the
Device Manager server database each time this command is executed.
NOTE:
To specify a storage system and then refresh its configuration information, use the AddStorageArray
command. When the storage system already exists, the AddStorageArray command performs a
re-discovery operation on the storage system and refreshes the registered information on the Device
Manager server database.
Parameters
Table 73 RefreshStorageArrays command parameter
DescriptionStatusParameter name
Either of the following values can be specified to determine how
storage systems are refreshed:
1: Refreshes storage systems sequentially.
2: Refreshes multiple storage system in parallel.
#
The default is 1.
Optional
refreshmode
CLI Reference Guide 205