HP P9000 Command View Advanced Edition Suite Software 7.2 CLI Reference Guide

svolhostid=host-ID svolinstancenum=instance-number [svolportnum=port-number]
pvolarraytype=model pvolserialnum=serial-number pvoldevnum=device-number
[pvolportid=port-number|pvolportname=port-name] pvolpoolid=pool-ID
svolarraytype=model svolserialnum=serial-number svoldevnum=device-number
[svolportid=port-number|svolportname=port-name] svolpoolid=pool-ID
replicationfunction={BusinessCopy|ContinuousAccessSync|ContinuousAccessAsync
|Snapshot|ContinuousAccessJournal} [munum=Mu-number]
Method 3: Creates a new RAID Manager configuration definition file. To use this method, execute
the command in the following format:
hdvmcli [URL] AddConfigFileForReplication [options]
[groupname=copy-group-name]
pvolhostid=host-ID [pvolinstancenum=instance-number] pvolportnum=port-number
svolhostid=host-ID [svolinstancenum=instance-number] svolportnum=port-number
pvolarraytype=model pvolserialnum=serial-number pvoldevnum=device-number
[pvolportid=port-number|pvolportname=port-name] pvolpoolid=pool-ID
svolarraytype=model svolserialnum=serial-number svoldevnum=device-number
[svolportid=port-number|svolportname=port-name] svolpoolid=pool-ID
replicationfunction={BusinessCopy|ContinuousAccessSync|ContinuousAccessAsync
|Snapshot|ContinuousAccessJournal} [munum=Mu-number]
Parameters
Table 101 AddConfigFileForReplication command parameters
DescriptionStatusParameter name
Group name used in the RAID Manager
You can use a maximum of 31 bytes. You cannot specify a name
that begins with a hash mark (#) or hyphen (-).
When using Method 1, specify a group name that is specified in
the definition file.
You must specify this parameter when you are using method 1.
Optional
groupname
Host ID for identifying the P-VOL
When using Method 1, specify the host ID of the P-VOL in a group
specified in the definition file.
Required
pvolhostid
Instance number of the HORCM instance for managing the P-VOL
When using Method 1, specify the instance number of the P-VOL
of a group specified in the definition file.
You must specify this parameter when you are using method 1
or 2.
Optional
pvolinstan-
cenum
Port number of the HORCM instance for managing the P-VOL
Depending on the host OS, specify the appropriate value:
In Solaris, specify an integer from 0 to 65535.
In AIX, Windows, HP-UX, and Linux, specify an integer from
1 to 65535.
This parameter is invalid when the pvolinstancenum is
specified.
You must specify this parameter when you are using method 3.
Optional
pvolportnum
CLI Reference Guide 269