HP P9000 Command View Advanced Edition Suite Software 7.2 CLI Reference Guide

DescriptionStatusParameter name
Type of operation that is to be executed with the copy pair
You can specify the following values:
BusinessCopy: Business Copy Software
ContinuousAccessSync: Continuous Access Synchronous
Software
ContinuousAccessAsync: Continuous Access Asynchron-
ous Software
Snapshot: Snapshot
ContinuousAccessJournal: Continuous Access Journal
Software
Required
replication-
function
MU number of the P-VOL
This parameter can be specified only for Continuous Access
Journal Software.
For Continuous Access Journal Software if this parameter is not
specified, the MU number of the created HORCM configuration
file for RAID Manager is set to 1.
For Business Copy Software or Snapshot, the MU number of the
created HORCM configuration file for RAID Manager is set to 0.
For Continuous Access Software, the MU number of the HORCM
configuration file for RAID Manager is not set because the MU
number is not necessary for Continuous Access Software.
Optional
munum
Specify this parameter to create the configuration of the 3DC
delta resync.
You can specify suspend only.
This parameter can be specified only when Continuous Access
Journal Software is being used.
Optional
pairoption
#
To operate a specific copy pair in a copy group, you must specify all of the pvolserialnum,
pvoldevnum, svolserialnum, and svoldevnum parameters. If you omit all of these para-
meters, all the copy pairs in the copy group will be changed.
Parameter values to obtain in advance
Parameter values to obtain in advance depend on how you will create a configuration definition file.
When using Method 1 (when adding a copy pair definition to a copy group in which another
copy pair has been defined):
See No. 1, No. 5, and No. 6 in the table below.
When using Method 1 (when adding a copy pair definition to a copy group in which no copy
pair has been defined):
See No. 2, No. 3, No. 5, and No. 6 in the table below.
When using Method 2:
See No. 2, No. 4, No. 5, No. 6, and No. 7 in the table below.
When using Method 3:
Command reference272