HP P9000 Command View Advanced Edition Suite Software 7.2 CLI Reference Guide

DescriptionStatusParameter name
Specify one of the following values:
split: Split the copy pair.
resync: Re-synchronize the copy pair from the primary
volume (P-VOL) to the secondary volume (S-VOL).
restore: Re-synchronize the copy pair from the S-VOL to the
P-VOL.
If you re-synchronize a Snapshot copy pair, the copy pair is split
after the re-synchronization. For this reason, the paired volume
status is set to PAIR, and then changes toPSUS.
Required
operation
Serial number of the storage system that contains the P-VOLOptional
pvolserialnum
#
Device number of the P-VOL
This parameter can be specified in decimal, and in
colon-separated hexadecimal. If you specify a hexadecimal
number, for XP12000/XP10000/SVS200 and XP1024/XP128,
use the xx:yy format, where xx is the CU number, and yy is
the LDEV number. For P9500 and XP24000/XP20000, use the
ww:xx:yy format, where ww is the LDKC number, xx is the CU
number, and yy is the LDEV number. ww is optional. If you omit
ww, the LDKC number is regarded as 0.
The execution results are output in decimal.
Optional
pvoldevnum
#
Serial number of the storage system that contains the S-VOL
If you specify this parameter, specify either svolserialnum or
svolsequencenum. Do not specify both parameters at the same
time. If they are specified at the same time, an error will occur.
Optional
svolserialnum
#
Sequence number of the storage system that contains the S-VOL
If you specify this parameter, specify either svolserialnum or
svolsequencenum. Do not specify both parameters at the same
time. If they are specified at the same time, an error will occur.
Optional
svolsequen-
cenum
#
Device number of the S-VOL
This parameter can be specified in decimal, and in
colon-separated hexadecimal. If you specify a hexadecimal
number, for XP12000/XP10000/SVS200 or XP1024/XP128,
use the xx:yy format, where xx is the CU number, and yy is
the LDEV number. For P9500 or XP24000/XP20000, use the
ww:xx:yy format, where ww is the LDKC number, xx is the CU
number, and yy is the LDEV number. ww is optional. If you omit
ww, the LDKC number is regarded as 0.
The execution results are output in decimal.
Optional
svoldevnum
#
CLI Reference Guide 295