HP P9000 Command View Advanced Edition Suite Software 7.2 CLI Reference Guide

DescriptionAttribute
Port ID
portID
Domain ID of the host storage domain
domainID
SCSI ID assigned to a channel in the storage system
15 is output for Fibre Channel.
scsiID
LUN of a logical unit in the storage system
lun
Device number of the logical unit
devNum
Number of the SCSI bus on the host
osScsiBus
SCSI ID assigned to a channel on the host
If this value is 64000, the values for osScsiID, osScsiBus, and osLun are
invalid.
osScsiID
LUN of a logical unit on the host
osLun
WWN of the port in the host bus adapter
portWWN
Type of the file system to be mounted
The name of the disk type (Datastore or Raw LUN) is output for a virtualization
server. Note that if the volume is not used as a datastore or Raw Device Mapping,
a space is output.
fileSystemType
File system name
A space is output for a virtualization server.
fileSystemName
Datastore name for a virtualization server
Datastore identification name or datastore mapping file name is output for a
virtualization server.
If the volume is not used as a datastore or Raw Device Mapping, a space is output.
This item is output only for a virtualization server.
datastoreName
LUN size (in MB)
sizeInMB
Rate of LUN usage (%)
percentUsed
Latest update time of data
The number of seconds elapsed from 00:00:00 on January 1, 1970 (world
standard time) is displayed.
lastUpdated
Port name
portName
Display name of the logical unit device number
For P9500 or XP24000/XP20000:
The value is output in the ww:xx:yy format, where ww is the logical DKC
number, xx is the CU number, and yy is the LDEV number.
For XP12000/XP10000/SVS200 or XP1024/XP128:
The value is output in the xx:yy format, where xx is the CU number and yy
is the LDEV number.
displayDevNum
CLI Reference Guide 311