HP P9000 Command View Advanced Edition Suite Software 7.2 CLI Reference Guide

When creating multiple logical units in bulk by specifying their number:
hdvmcli [URL] AddLogicalUnit [options]
serialnum=serial-number model=model
{chassis=chassis-number
groupnum=parity-group-number|arraygroupname=parity-group-name}
[fsindex=index-number-of-region-of-unused-capacity] creationoption=dividebynum
numoflus=number-of-logical-units-to-be-created [emulation=OPEN-V]
[devnum=logical-unit-device-number] [lusubinfo=LDEV]
[format={none|normal|quick
#
}] [capacitytype={KB|block}]
#
For the XP24000/XP20000, you can specify quick for the format parameter.
Format for XP1024/XP128
hdvmcli [URL] AddLogicalUnit [options]
serialnum=serial-number model=model
{chassis=chassis-number
groupnum=parity-group-number|arraygroupname=parity-group-name}
capacity=capacity-of-the-logical-unit [emulation=emulation-type]
[devnum=logical-unit-device-number] [lusubinfo=LDEV]
Parameters
Table 25 AddLogicalUnit command parameters
DescriptionStatusParameter name
Serial number of the storage system where the LU is addedRequired
serialnum
Model of the storage system where the LU is addedRequired
model
Number of the chassis for the parity group where the LU is added
If you specify this parameter, make sure that groupnum is also
specified.
Always specify either the chassis and groupnum parameters
together, or the arraygroupname parameter by itself. Do not
specify arraygroupname together with chassis and
groupnum. Doing so will result in an error.
Optional
chassis
Number of the parity group where the LU is added
If you specify this parameter, make sure that groupnum is also
specified.
Always specify either the chassis and groupnum parameters
together, or the arraygroupname parameter by itself. Do not
specify arraygroupname together with chassis and
groupnum. Doing so will result in an error.
Optional
groupnum
Command reference58