HP P9000 Command View Advanced Edition Suite Software 7.2 CLI Reference Guide

DescriptionStatusParameter name
An option for adding a LUSE volume to a volume for which
a path is set
The value you can specify is force only.
For XP1024/XP128, the microcode version must be
21-05-00/00 or later when this option is specified.
Optional
luseoption
Parameter values to obtain in advance
serialnum and model
Obtain these values from the execution result of the GetStorageArray command. In the execution
result, use the arrayType value or the displayArrayType value to specify the model para-
meter, and use the serialNumber value to specify the serialnum parameter.
devnums
Obtain this value from the execution result of the GetStorageArray (subtarget=LDEV)
command. Execute this command by specifying only the model and serialnum parameters,
and LDEV for the subtarget parameter. In the execution result of this command, the devNum
value of an LDEV appears under An instance of LDEV. Use this devNum value to specify
the devnums parameter.
Command execution example
hdvmcli AddLUSE -o "D:\logs\AddLUSE.log"
"serialnum=15001" "model=XP1024" "devnums=1001,1002"
Command execution result
RESPONSE:
An instance of StorageArray
.
. (Attributes of StorageArray are omitted here)
.
List of 1 Lu elements:
An instance of LogicalUnit
objectID=*****
devNum=1,001
displayName=03:E9
emulation=OPEN-3
devCount=2
devType=
capacityInKB=4,806,720
path=false
commandDevice=false
commandDeviceEx=0
commandDeviceSecurity=false
chassis=3
arrayGroup=16
arrayGroupName=3-2-1
raidType=RAID5(3D+1P)
currentPortController=-1
Command reference64