HP P9000 Command View Advanced Edition Suite Software 7.2 CLI Reference Guide

DescriptionStatusParameter name
Device number of the logical unit(s)
Specify this parameter as a decimal number or
colon-delimited hexadecimal number in the format
ww:xx:yy, where ww is the LDKC number, xx is the CU
number, and yy is the LDEV number. ww is optional. If ww
is omitted, LDKC is assumed to be 0.
Use a comma to delimit multiple values.
Required
devnums
Specify whether to create the pool for Smart Tiers.
One of the following values can be specified.
enable: Creates the pool for Smart Tiers.
disable: Creates the pool for Thin Provisioning Soft-
ware.
If this parameter is omitted, enable is set.
Optional
(P9500)
tiercontrol
Specify whether to automatically execute performance
monitoring and hardware tier relocation.
If you specify this parameter, you must also specify
tiercontrol=enable.
One of the following values can be specified.
enable: Performs automatic execution.
disable: Does not perform automatic execution.
If this parameter is omitted, enable is set.
Optional
(P9500)
automigration
Execution cycle of performance monitoring and hardware
tier relocation.
If you specify this parameter, you must also specify
automigration=enable.
One of the following values can be specified.
0: 30 minutes
1: 1 hour
2: 2 hours
4: 4 hours
8: 8 hours
24: 24 hours
You can specify 0 only when the microcode version is
70-02-XX-XX/XX or later.
If this parameter is omitted, 24 is set when
monitoringmode is set to 0 (Periodic), and 1 is set when
monitoringmode is set to 1 (Continuous) .
Optional
(P9500)
migrationinter-
val
Start time of performance monitoring
If you specify this parameter, you must also specify
migrationinterval=24.
Specify a time in the range from 00:00 to 23:59 in HH:MM
format.
If this parameter is omitted, 00:00 is set.
Optional
(P9500)
monitorstart-
time
#3
CLI Reference Guide 71