Table 20 RAID Manager errors related to migration plans (continued)
Required ActionMessageError Code
(SSB2)
The volume cannot be migrated. Check the
configuration definition file.
If the serial number of the virtual storage machine
is set to the primary and secondary volume, the
20F2
serial number set in the primary volume matches
the serial number set in the secondary volume.
However, the serial numbers of the physical
storage systems and the virtual storage machines
do not match.
The volume cannot be migrated. Check the
configuration definition file.
The pair cannot be operated because the specified
migration source volume is the secondary volume
20F9
of the Business Copy pair whose primary volume
is in the process of the online data migration.
Release the Compatible FlashCopy pair, and then
migrate the volume.
The migration source volume is the source or target
volume of Compatible FlashCopy.
22FA
Release the Compatible FlashCopy pair, and then
migrate the volume.
The migration target volume is the primary or
secondary volume of Compatible FlashCopy.
22FB
Install Auto LUN, and then migrate the volume.Auto LUN is not installed on the storage system.2301
Check the configuration information of your
storage system.
The shared memory which is necessary to use Auto
LUN is not installed or the initial setting is not
completed.
2302
The volume cannot be migrated. Check the
configuration definition file.
The LBA size does not match between the
migration target volume and the migration source
volume.
2306
Reduce the number of pairs set in the storage
system, and then migrate the volume.
The maximum number of pairs which can be set
in the storage system is exceeded.
2309
Make the migration target volume off-line from the
host, and then migrate the volume.
The migration target volume is online with the host.2312
Release the Business Copy pair, and then migrate
the volume.
The migration source volume is set as the leaf
volume of Business Copy
2322
Release the Business Copy pair, and then migrate
the volume.
The migration target volume is set as the secondary
volume of Business Copy.
2328
Release the volume from Auto LUN, and then
migrate the volume.
The migration source volume is already specified
as the target volume of Auto LUN.
232F
The volume cannot be migrated. Check the
configuration definition file.
The number of slots does not match between the
migration target volume and the migration source
volume.
2331
Reduce the number of pair settings of the specified
volume, and then migrate the volume.
You cannot add pair settings any more to the
volume specified as the migration source.
2332
None. The specified volume is not a source
volume.
The volume specified by the migration cancellation
is not a migration source volume
2333
The volume cannot be migrated. Check the
configuration definition file.
The emulation type does not match between the
migration target volume and the migration source
volume.
2336
Release the Business Copy pair, and then migrate
the volume.
The migration source volume is a leaf volume of
Business Copy.
2337
Release the Business Copy pair, and then migrate
the volume.
The migration target volume is a primary volume
of Business Copy.
233B
Release the Business Copy pair, and then migrate
the volume.
The migration target volume is a secondary volume
of Business Copy.
233C
36 Using RAID Manager for Auto LUN