Table 20 RAID Manager errors related to migration plans (continued)
Required ActionMessageError Code
(SSB2)
The volume cannot be migrated. Check the
configuration definition file.
The migration source volume is a command device.2373
Release the Continuous Access Synchronous pair,
and then migrate the volume.
The migration source volume is an external volume
specified as a primary volume of Continuous
Access Synchronous.
237C
The volume cannot be migrated. Check the
configuration definition file.
The migration target volume is not installed.2380
Recover the blocked volume, and then migrate the
volume.
The migration target volume is blocked.2381
Migrate the volume after formatting or shredding
is completed.
The migration target volume is being formatted or
being shredded.
2382
The volume cannot be migrated. Check the
configuration definition file.
The migration target volume is a command device.2383
Release the setting of Cache Residency, and then
migrate the volume.
Cache Residency is set on the migration source
volume.
2389
Release the setting of Cache Residency, and then
migrate the volume.
Cache Residency is set on the migration target
volume.
238A
Perform the user authentication.The command cannot be executed because the
user authentication is not performed.
9100
Make sure that the specified volume is
implemented.
The pair operation command was rejected
because the specified volume is not implemented.
B911
Make sure that the specified secondary volume is
implemented.
The pair operation command was rejected
because the specified secondary volume is not
implemented.
B912
Specify the mirror ID from 0 to 2.The pair operation command was rejected
because the mirror ID is invalid.
B913
38 Using RAID Manager for Auto LUN