HP XP7 Provisioning for Open Systems User Guide (H6F56-96009)

DescriptionItem
For a Thin Provisioning pool, THP is displayed.
For a Smart Tiers pool, Smart is displayed.
For a Thin Provisioning Z pool, Mainframe THP is displayed.
For a Smart Tiers Z pool, Mainframe Smart is displayed.
For a Fast Snap pool, FS is displayed.
Displays the data drive type and RPMs. If multiple drive types or RPMs exist in
a pool, this field indicates Mixed. When the volume is the external volume, Drive
Drive Type/RPM
Type displays External Storage and the value of the external LDEV tier rank. If
all pool-VOLs are external volumes, a hyphen (-) is displayed.
Displays the pool threshold.User-Defined Threshold (%)
Warning: Warning threshold is displayed.
Depletion: Depletion threshold is displayed.
For a Fast Snap pool, a hyphen (-) is displayed for Depletion.
Displays the subscription limit.Subscription Limit (%)
For Fast Snap pool, a hyphen (-) is displayed.
Displays the number of pool-VOLs.Number of Pool VOLs
If Smart Tiers or Smart Tiers Z is enabled, Auto or Manual for performance
monitoring and tier relocation is displayed. If Smart Tiers or Smart Tiers Z is
disabled, a hyphen (-) is displayed.
Tier Management
Displays the cycle of performance monitoring and tier relocation. If Smart Tiers
or Smart Tiers Z is disabled, a hyphen (-) is displayed.
Cycle Time
Displays the time zone of performance monitoring when 24 Hours is selected
as the Cycle Time. If Smart Tiers or Smart Tiers Z is disabled, a hyphen (-) is
displayed.
Monitoring Period
If the continuous mode is enabled, Continuous Mode is displayed. If the period
mode is enabled, Period Mode is displayed.
Monitoring Mode
Displays the page relocation speed: 1(Slowest), 2(Slower), 3(Standard), 4(Faster),
or 5(Fastest). If Smart Tiers or Smart Tiers Z is disabled, a hyphen (-) is displayed.
Relocation Speed
Displays the information of the buffer space for new page assignment to each
tier.
Buffer Space for New page
assignment (%)
Tier 1: If you make the Smart Tiers or Smart Tiers Z function available, the buffer
space for new page assignment to tier 1 is displayed. If you make the Smart
Tiers or Smart Tiers Z function unavailable, a hyphen (-) is displayed.
Tier 2: If you make the Smart Tiers or Smart Tiers Z function available, and tier
2 exists, the buffer space for new page assignment to tier 2 is displayed. If you
make the Smart Tiers or Smart Tiers Z function unavailable, or tier 2 does not
exist, a hyphen (-) is displayed.
Tier 3: If you make the Smart Tiers or Smart Tiers Z function available, and tier
3 exists, the buffer space for new page assignment to tier 3 is displayed. If you
make the Smart Tiers or Smart Tiers Z function unavailable, or tier 3 does not
exist, a hyphen (-) is displayed.
Displays the information of the buffer space for tier relocation to each tier.Buffer Space for Tier relocation (%)
Tier 1: If you make the Smart Tiers or Smart Tiers Z function available, the buffer
space for tier relocation to tier 1 is displayed. If you make the Smart Tiers or
Smart Tiers Z function unavailable, a hyphen (-) is displayed.
Tier 2: If you make the Smart Tiers or Smart Tiers Z function available, and tier
2 exists, the buffer space for tier relocation to tier 2 is displayed. If you make
the Smart Tiers or Smart Tiers Z function unavailable, or tier 2 does not exist, a
hyphen (-) is displayed.
Edit Pools wizard 341