HP StorageWorks External Storage XP user guide for the XP12000, XP10000, SVS200 (T1706-96009, October 2007)

Table 2 Storage arrays that can be connected as external arrays
Storage array
Notes
HP StorageWork
s XP12000 Disk Array
In External Storage XP panes, the array appears
as “12000”.
Alternate paths are in Multi mode (meaning that
dynamic load balancing across multiple active
pathsisenabled).
HP StorageWorks XP10000 Disk Array
In External Storage XP panes, the array appears
as “10000”.
Alternate paths are in Multi mode.
HP StorageWorks XP1024/XP128 Disk Array
In External Storage XP panes, the arrays appear
as “1024” and “128”, respectively.
Alternate paths are in Multi mode.
HP StorageWorks XP512/XP48 Disk Array
In External Storage XP panes, the arrays appear
as “512” and “48”, respectively.
Alternate paths are in Multi mode.
HP StorageWorks XP256 Disk Array
In External Storage XP panes, the array appears
as “256”.
Alternate paths are in Multi mode.
HP StorageWorks 200 Storage Virtualization System
In External Storage XP panes, the array appears
as “SVS200”.
Alternate paths are in Multi mode.
HP StorageWorks 3000/5000 Enterprise Virtual
A
rray (Active/Standby and Active/Active controllers)
o
r HP StorageWorks 4000/6000/8000 Enterprise
Virtual Array (Active/Active controllers)
In this user guide, the arrays appear as EVA
array”.
In External Storage XP panes, the arrays appear
as “EVA.
AlternatepathsareinSinglemode(meaningthat
dynamic load balancing across multiple active
paths is not enabled).
HP StorageWorks MSA1000/1500 (Active/Standby)
In this user guide, the arrays appear as “MSA
array”.
In External Storage XP panes, the arrays appear
as “MSA.
Alternate paths are in Single mode.
TagmaStore™ Universal Storage Platform subsystem
In this user guide, the array appears as
“TagmaStore™ USP subsystem”.
In External Storage XP panes, the array appears
as “USP”.
Alternate paths are in Multi mode.
TagmaStore™ Network Storage Controller subsystem
In this user guide, the array appears as
“TagmaStore™ NSC subsystem”.
In External Storage XP panes, the array appears
as “NSC”.
Alternate paths are in Multi mode.
TagmaStore™ Adaptable Modular Storage subsystem
In this user guide, the array appears as
“TagmaStore™ AMS subsystem.
In External Storage XP panes, the array appears
as AMS”.
Alternate paths are in Single mode.
18
Preparing for External Storage XP operations