HP StorageWorks External Storage XP user guide for the XP12000, XP10000, SVS200 (T1706-96009, October 2007)

NOTE:
To perform Discovery operations, Command View XP or XP Remote Web Console must
be in Modify mode.
5. Display the LU Operation pane, right-click the external LU to be mapped as an internal LDEV in the
Device list, and select Add LU or Add LU (Auto). The Add LU or Auto Map Setting pane appears.
6. UsetheAddLUorAutoMapSettingspanetomaptheexternalLUasaninternalLDEV(Mapping
external LUs (Add LU)).
7. If you select a mainframe emulation type on the Add LU pane, use Volume Manager to reformat the
volume or perform the Write to Control Blocks operation. For instructions, (see the HP StorageWorks
LUN Conguration and Security Manager XP user guide for the XP12000/XP10000/SVS200.
8. Dene alternate paths between the external array or mapped LU and the local array. For instructions,
see Dening alternate paths.
9. Use LUN Manager to dene paths. For instructions, see the HP StorageWorks LUN Conguration
and Security Manager XP user guide for the XP12000/XP10000/SVS200.
Setting an external array's port
This section describes the procedure for setting the external array's port. For more information, see the
external array's documentation.
1. Set the topology information for the connection conguration.
2. Set the data transfer speed for the conguration.
3. Set the system parameters. For more information about system parameters for specicexternal
arrays, see Notes on connecting external arrays.
4. Dene the port's LUN.
Setting a local array's port attributes
The attribute of any port used for External Storage XP must be set to External.
NOTE:
OnlyportsinSLPR0canbesetasexternalports.
NOTE:
The por
ts that can be set as external ports are only the ports serving LDEVs, belonging to CU group 0. If
the storage is partitioned by using Virtual Partition Manager, the ports that can be set as external ports
are only the ports serving LDEVS associated with CU group 0, and are allocated to SLPR 0 as well.
1. Select the Port Operation tab.
2. In the Port Operation list, select the port.
TosetmultipleportsatonetimetoExternal, select all the ports.
3. Right-click, and select Change to External.
In the Port Operation list, the selected port's attribute changes to External, and the selected port's
row appears in blue italics. Rows to be affected appear in the Preset list. To check setting details,
right-click the setting in the Preset list, and select Detail. To cancel settings, right-click the setting
in the Preset list, and select Delete.
78
Conguring external LUs