HP StorageWorks External Storage XP user guide for the XP12000, XP10000, SVS200 (T1706-96009, October 2007)

As long as the external array uses Symmetrical Active/Active controllers (for example, XP), change an
alternate path to the currently used path by simply raising the priority of the alternate path or lowering
the priority of the currently used path.
NOTE:
If the two paths connect to different controllers on the external array (for example, MSA), do not use
a path priority change to attempt to force a controller failover. Instead, use either a manual cable
disconnect or a Disconnect Paths GUI operation on the active controller WWN in the device list. In other
words, while the XP rmware may respond to a cable disconnect leading to the primary path and active
controller as a reason to activate the passive controller and path and continue I/Os, a simple change in
path priorities may not have the same effect, and I/Os may become blocked.
1. Select the LU Operation tab. The LU Operation pane appears.
2. In the Device tree, select the external LU group number. Information about the external LU mapped
as an internal LDEV appears in the Device list.
3. In the Device list, right-click the external LU, and select Path Setting.ThePathSettingwindow
(Figure 51)appears.
4. Detailed information about the currently used path and alternate path appears in the Congured
Paths table, and paths that can be dened as alternate paths appear in the Available Paths table.
5. In the Congured Paths table, right-click the row of the path dened as the alternate path, and select
Priority Up (Figure 52). The row for the selected path switches with the row above it. The alternate
path's priority is raised, and the path is set as the currently used path.
Figure 52 Path Setting window, shortcut menu
6. Repeat the Priority Up command until the row of the selected path is displayed on the rstlineofthe
Congured Path list and that row's Priority column changes to 1.
When the Priority column changes to 1, the path is set as the typically used one (primary path).
7. Click OK. The Path Setting window closes, and the LU Operation pane appears.
External Storage XP user guide
99