Owner's manual

The following information displays for each controller:
Model—Displays the type of controller card.
Controller Status—Displays the array controller board status. The following values are valid:
OK—The array controller is operating properly.
General Failure—The array controller has failed.
Cable Problem—The array controller has a cable problem. Check all cables to the
controller.
Powered Off—The array controller does not have power. Replace the controller and
restore power to the controller's slot.
Unknown—Indicates that the Storage Agents are unable to determine the status of the
controller. You may need to upgrade the Storage Agents.
Current Role—Displays the array controller's current role for duplexed array controllers. The
following values are valid:
Not Duplexed—This array controller is not duplexed.
Active—This duplexed array controller is the active controller.
Backup—This duplexed array controller is the backup controller.
Unknown—Indicates that the Storage Agents are unable to determine the role of the
controller. You may need to upgrade the Storage Agents.
Redundancy Mode—Displays the redundancy type for the controller. The following values are
valid:
Not Redundant—This array controller is not in a redundant configuration.
Driver Duplexing—The array controller is using a controller duplexing algorithm
implemented exclusively in the operating system driver.
Firmware Active/Standby—The array controller is using an active/standby algorithm
implemented in the controller firmware and the operating system driver.
Firmware Primary/Secondary—The array controller is using a primary/secondary
algorithm implemented in the controller firmware and the operating system driver.
Firmware Active/Active—The array controller is using an active/active algorithm
implemented in the controller firmware.
Unknown—Indicates that the Storage Agents cannot determine the redundancy type for
the controller. You may need to upgrade the Storage Agents.
Redundancy Error—Displays the redundancy error for the controller. The following values are
valid:
No Failure—No failures have been detected.
No Redundant Controller—No redundant controller is installed.
Different Hardware—The other controller indicates a different hardware model.
No Link—A link to the other controller could not be established.
Different Firmware—The other controller indicates a different firmware version.
Different Cache—The other controller indicates a different cache size.
Other Cache Failure—The other controller indicates a cache failure.
No Drives—This controller cannot see any attached drives, but the other controller can.
Other No Drives—This controller can see the attached drives, but the other controller
cannot.
34 Agent information