Owner manual

Agent information 54
SAS AttachedThis chassis is attached to the server with a SAS cable.
UnknownThe Storage Agents are unable to determine the type of connection.
Drive Bays—Displays the number of drive bays provided by this storage system. If duplexing hardware is used
with the storage system, the drive bay number is less than the number of physical drive bays in the enclosure.
Model—Displays the model of the storage system. Use this information for identification purposes.
Board Revision—Displays the board revision level of this storage system backplane.
Thermal Status—Displays the temperature status of the drive system. The following values are possible:
OKThe temperature is within normal operating range.
DegradedThe temperature is outside of normal operating range. Check to make sure the cover is on the
storage system.
FailedThe temperature is outside of normal operating range, and could permanently damage the system.
Ensure that the fans are spinning, and check the room temperature.
UnknownThe Storage Agents do not recognize the thermal status. You may need to upgrade your
software.
No Temperature MonitoringThis storage system does not support temperature monitoring.
Side Panel—Displays the status of the side panel of the drive enclosure, or box. The following values are
possible:
In PlaceThe side panel is closed.
RemovedThe side panel is not in place or not completely closed.
UnknownThe Storage Agents do not recognize the side panel status. You may need to upgrade your
software.
No Panel DetectionThis storage system does not support side panel detection.
Duplex Option—Displays the duplex option installed in this storage system. The following values are possible:
Duplex TopThis storage system is the top part of a duplexed unit.
Duplex BottomThis storage system is the bottom part of a duplexed unit.
NoneA duplex option is not installed.
Power Supply Status—Displays the status of the redundant power supply. The following values are possible:
OKAll component power supplies that make up the redundant power supply are in normal working order.
DegradedOne of the component power supplies that make up the redundant power supply has failed.
The drive system (either a drive subsystem or a power supply for the main unit) continues to operate;
however, if the remaining power supply should fail, the drive system loses power and data loss could occur.
To correct this situation, schedule a time to bring the device down and replace the failed power supply.
UnknownThe Storage Agents do not recognize the redundant power supply. You may need to upgrade
your software.
No Redundant Power SupplyThis ProLiant server does not support a redundant power supply.
Paths—Displays the status and role of each data path to
the storage system (for multipath capable hardware
only). The following values are possible:
Path—Indicates the path to the storage system. Each path is identified by a descriptor. For example, "Port
2E Box 1" indicates a path from the host adapter external port number 2 ("Port 2E") to the first box.
Status—Indicates the status of the data path. Possible values are:
OKThe path is operational.
Link downThe path is not operational.
UnknownThe path status cannot be determined.
Role—Indicates the role of this path in the configuration. Possible values are:
Active—This path is the preferred data path to the storage system.
Alternate—This path is the alternate data path to the storage system.
Unknown—The role of this path cannot be determined.
IDE controllers
Select an IDE controller entry from the Mass Storage list to display a submenu containing separate entries for IDE
controller information, IDE ATA disk drives connected to the controller, and IDE ATAPI devices connected to the
controller. Device types include disks, DVD/CD-ROM drives, tape drives, processors, scanners, optical drives,
WORM drives, and so on. The following items might appear depending on the type of controller:
IDE controller information
IDE ATAPI devices