Agent information 62
UnknownThe Storage Agents do not recognize the drive enclosure. You might need to upgrade your
software.
VendorDisplays the name of the vendor that produces this drive enclosure or box type. Use this information
for identification purposes.
ModelDisplays the model of the storage system. Use this information for identification purposes.
Firmware RevisionDisplays the firmware revision of the drive enclosure or box. Use this information for
identification purposes.
Board RevisionDisplays the board revision level of this storage system backplane.
Serial NumberDisplays the serial number of the drive enclosure or box. Use this information for identification
purposes.
Thermal StatusDisplays the temperature status of the drive system. The following values are possible:
OKThe temperature is within normal operating range.
DegradedThe temperature is outside of normal operating range. Be sure the cover is on the ProLiant
Storage System.
FailedThe temperature is outside of normal operating range, and could permanently damage the system.
Ensure that the fans are spinning and check the room temperature.
UnknownThe Storage Agents do not recognize the thermal status. You might need to upgrade your
software.
No TemperatureThis server does not support temperature monitoring.
Fan Status—Displays the status of the fan subsystem in the drive enclosure, or box. The following values are
possible:
OKThe fan subsystem is working properly.
FailedA fan has failed and there are not enough fans in the fan subsystem to keep the enclosure cool.
Check your fan subsystem as soon as possible. Continued operation might cause failure of the drives.
DegradedA fan has failed but there are still enough fans in the fan subsystem to keep the enclosure cool.
UnknownThe Storage Agents do not recognize the status of the fan subsystem. You might need to
upgrade your software.
No FanThis server does not have a fan.
Backplane SpeedDisplays the speed of the storage system backplane. The following values are possible:
Ultra3The storage system is capable of Ultra3 speeds.
Ultra320The storage system is capable of Ultra320 speeds.
UnknownThe Storage Agents are unable to determine the storage system backplane speed. You might
need to upgrade your software.
Drive BaysDisplays the number of drive bays provided by this storage system. If duplexing hardware is used
with the storage system, the drive bay number is less than the number of physical drive bays in the enclosure.
Duplex OptionDisplays the duplex option installed in this storage system. The following values are possible:
Duplex TopThis storage system is the top part of a duplexed unit.
Duplex BottomThis storage system is the bottom part of a duplexed unit.
NoneA duplex option is not installed.
Power Supply StatusDisplays the status of the Redundant Power supply. The following values are possible:
OKAll component power supplies that make up the redundant power supply are in normal working order.
DegradedOne of the component power supplies that make up the redundant power supply has failed.
The drive system (either a drive subsystem or a power supply for the main unit) continues to operate.
However, if the remaining power supply should fail, the drive system loses power and data loss could
occur. To correct this situation, schedule a time to bring the device down and replace the failed power
supply.
UnknownThe Storage Agents do not recognize the redundant power supply. You might need to upgrade
your software.
No Redundant Power SupplyThis ProLiant server does not support a redundant power supply.
SCSI physical drives
Select a SCSI physical drive from the SCSI controller submenu to display the following information:
StatusDisplays the status of the physical drive selected. The following values are valid:
OKThe physical drive is operating normally.
FailedThe physical drive has failed and can no longer return data. The drive might need to be replaced.