Owner manual

CR3500 RAID Array SCSI controller 86
FormattingThe drive is currently being formatted.
ActionProvides a brief description of an action you can take depending on the physical drive condition
Drive information
CapacityDisplays the total capacity of the selected drive in megabytes
Firmware VersionDisplays the firmware revision of the selected drive
Drive OwnerLists a descriptive name for the drive owner
ModelDisplays the model number of the selected drive
VendorDisplays the vendor of the selected drive
RAID Arrays
RAID ArraysLists the RAID arrays by channel number and SCSI ID
Mass Storage controller
This section displays Array Controller information.
Clustered RAID controller
Controller StatusDisplays the current controller status. The following conditions are valid:
OKAll controller functions are operating normally.
DegradedThe controller is operating in a degraded or reduced state.
FailedThe controller is inoperable.
Current RoleDisplays if the controller is in simplex or duplex role.
Firmware VersionDisplays the current software revision.
Serial NumberDisplays the controller serial number.
Drive OwnershipLists a descriptive name for the drive owner.
Rebuild RateDisplays the rebuild rate. The rebuild rate ranges from 1 to 100. The controller rebuilds while at
the same time it handles I/O activity. A rate below 50 emphasizes I/O response over the RAID rebuild. A rate
above 50 puts a higher priority on the RAID rebuild at the expense of I/O activity.
Create RateDisplays the create rate. The create rate ranges from 1 to 100. The controller creates RAID sets
while, at the same time, handles I/O activity. A rate below 50 emphasizes I/O response over the RAID set
creation. A rate above 50 puts a higher priority on the RAID set creation at the expense of I/O activity.
Cache SizeDisplays the cache size in megabytes.
DIMM A SizeDisplays the Dual Inline Memory Module A size in megabytes.
DIMM B SizeDisplays the Dual Inline Memory Module B size in megabytes .
Mass Storage Summary
CR3500 Shared Storage system
This section displays degraded or failed devices in the CR3500 Shared Storage system.
The following is a list of devices in CR3500 Shared Storage system:
Clustered RAID Controller
RAID Array
Physical Drive
Spare Drive
Environment Monitoring Unit
Environment Monitoring Unit
This section displays the Environment Monitoring Unit information.
Primary enclosure temperature statusDisplays the current primary enclosure temperature status. The following
conditions are valid:
OKThe primary enclosure temperature is within normal parameters.