Installation and Upgrade Guide

Loading the Previous RVU and Resuming Normal
Operations
G06.24 Software Installation and Upgrade Guide528593-005
17-5
Configure Spooler
Configure Spooler
RVUs for G06.00 and later RVUs contain spooler product version T9101D46, which
introduced a spooler control file in a new format. Although it is still a type 128 file,
internally it is considerably different from the format used in the base T9101D41
spooler. For this reason, it is not possible to warm start a version of the spooler prior to
T9101ADI with a control file produced by the T9101D46 or D48 product version of the
spooler. You must save the control files and collection data files before warm starting
the new version of the spooler.
In G06.03, T9101D48 was introduced and its control file is the same as the D46
version.
To return to the previous version of spooler:
1. Restore the control files.
2. Restore the collector files.
3. Warm start the previous version.
For detailed instructions on warm starting the spooler, see the Spooler Utilities
Reference Manual. See also Support Note S03006.