Instruction Manual

Access level/Bay level:
OA Administrator
Restriction:
None
ENABLE LLF
Command:
ENABLE LLF
Description:
Enables Link Loss Failover for Onboard Administrator Redundancy.
Access level/Bay level:
Operator, Administrator
Restrictions:
You must have OA permission to perform this command.
POWEROFF XFABRIC
Command:
POWEROFF XFABRIC
Description:
Powers off all Xbar Fabric modules
Access level/Bay level:
OA Administrator, OA Operator
Restrictions:
You must be logged on to the monarch OA to perform this command.
The POWEROFF XFABRIC command fails if all partitions are not shut down.
POWERON XFABRIC
Command:
POWERON XFABRIC
Description:
Powers on all Xbar Fabric modules
Access level/Bay level:
OA Administrator, OA Operator
Restrictions:
You must be logged on to the monarch OA to perform this command.
72 Enclosure management commands